Heat pumps
AC repair
Furnace & heating
Ductless mini splits
Carrier
Trane
GoodmanSeasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed
Diagnosis first, numbers second - you approve the repair price before a single part goes in.
Get your free estimateRheem Heat Pump Service: The Austin Owner’s Guide
Rheem heat pump repair in Austin typically runs $150 – $650 installed, with most common failures like capacitors, contactors, and defrost control boards landing in the $180 – $380 range. We stock Rheem-compatible parts on our trucks and can diagnose most systems same-day. The call usually starts with something simple: the outdoor unit won’t kick on, or it’s running but the air coming out of the vents isn’t warm (or cool) like it should be. By the time an Austin homeowner calls us, they’ve usually noticed the system cycling oddly for a few days before it finally quit. We’ll walk you through exactly what you’re dealing with.
We’re an independent Rheem service provider in Austin, not a factory affiliate. That means we fix the equipment honestly, stock the parts that actually fail, and tell you when a Rheem OEM part is worth the extra money and when a quality equivalent gets the job done for less.
Which Rheem Models This Applies To
We service the full Rheem heat pump lineup you’ll find in Austin homes: the RP14, RP15, RP16, RP17, and RP20 series, plus older RPGB and RPNL units that are still running in places like Allandale and Crestview. The model number is on a data plate riveted to the outdoor unit’s side panel, typically in the format “RP1436AJ1NA.” That string matters. The 36 tells you it’s a 3-ton unit, and the letters after it identify the refrigerant, voltage, and revision. Bring that number with you when you call, or shoot us a photo. It saves a trip and gets the right part on the truck the first time.
Here’s a Rheem-specific gotcha most Austin homeowners don’t know: Rheem heat pumps built before 2010 used R-22 refrigerant, while 2010-and-newer systems run R-410A. The outdoor units look nearly identical from a distance, but the parts inside, especially reversing valves and metering devices, are not interchangeable. A defrost board from an R-22 unit won’t function correctly on an R-410A system even if the connector fits. We check the data plate before we order anything.
On the OEM-versus-aftermarket question: for control boards, sensors, and thermostats, we recommend Rheem OEM parts because they’re flashed with Rheem-specific firmware and timing curves. For capacitors, contactors, and fan motors, we regularly install proven aftermarket equivalents from AmRad, Packard, and Mars that meet or exceed the original spec, often for 20 – 30% less. If you want OEM on everything, we’ll price it that way, and we’ll be honest when it’s overkill.
Styles & brands we work with







Signs Your Rheem Heat Pump Service Is Failing
- Outdoor unit won’t start, but the indoor blower runs. Most often a failed run capacitor or a pitted contactor. The capacitor gives the compressor and fan motor their starting jolt. In Austin’s summer heat, capacitors can cook themselves in three or four seasons, especially if the outdoor unit sits in full sun on a west-facing wall.
- System runs, but blows lukewarm air in heating mode. This usually points to a stuck reversing valve or a refrigerant charge that’s drifted low. The reversing valve is what makes a heat pump a heat pump. It flips refrigerant flow to switch between cooling and heating. When it sticks midway, you get neither.
- Outdoor unit freezes up in winter, and the system goes into a defrost cycle that won’t end. The defrost control board or the defrost thermostat sensor has failed. Rheem units use a demand-defrost logic that measures coil temperature and outdoor air temperature. When the sensor reads wrong, the board either defrosts constantly or never, both of which kill efficiency and eventually the compressor.
- You hear a loud buzz or click from the outdoor unit, then silence. Classic contactor failure. The contactor is an electrical switch that feeds power to the compressor and fan. In Austin’s clay-heavy soil, ants love building nests in the contactor gap. We pull dozens of ant-fried contactors every spring. A simple replacement is one of the cheapest repairs we do.
- Electric heat strips run constantly, or the thermostat shows “aux heat” even in mild weather. The heat pump has been locked out by the control board, often because it detected a compressor or sensor fault. Your bills spike quickly. This is the system telling you it needs service before a small part fails into a big one.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
Here’s what Rheem heat pump repairs cost in Austin, parts and labor included:
- Run capacitor replacement: $150 – $250
- Contactor replacement: $150 – $250
- Defrost control board (OEM Rheem): $250 – $420
- Defrost thermostat/sensor: $170 – $280
- Reversing valve replacement: $420 – $650
- Condenser fan motor: $280 – $450
- Refrigerant leak repair and recharge: $300 – $650
The spread depends on which part your system needs, the age of the unit, and how much refrigerant or auxiliary work is involved. You get a written price before any work starts, always. That price covers the part, the labor to install it, and a written guarantee on the repair. If the same part fails within the guarantee period, we come back at no charge. That’s the 365-Day Done Right Promise, and it’s on every Rheem repair we do in Austin.
DIY or Call Us?
There are two things you can safely check before you call. First, look at your thermostat. Make sure it’s set to “heat” or “cool” and the system switch is on. Second, check the breaker panel for a tripped double-pole breaker on the outdoor unit. If you reset it and it trips again within minutes, stop. Do not reset it a third time. A breaker that trips repeatedly is telling you there’s a short to ground, usually in the compressor or a fan motor, and continued resetting can cause a fire or destroy the compressor entirely.
Everything beyond that, capacitor testing, contactor inspection, refrigerant diagnostics, reversing valve evaluation, involves live 240-volt electricity and high-pressure refrigerant. These are not forgiving systems. A capacitor that’s not properly discharged can deliver a shock that kills. Refrigerant handled wrong can cause frostbite burns or worse. Rheem heat pumps are well-built machines, but they’re not meant to be opened by someone without the right tools and training. If you’ve got one of the symptoms above, call us at (361) 326-1553. A diagnostic visit tells you exactly what’s wrong, what it costs to fix, and what we’d do if it were our own house.
FAQs
Run capacitors typically last 3 – 7 years in Austin, contactors 5 – 10 years depending on ant activity and electrical load, and defrost control boards 8 – 15 years. The heat and humidity here are harder on electrical components than the runtime hours alone would suggest. A part that might last 12 years in a milder climate can fail at year 7 in full Texas sun. If your system is 8+ years old and the original capacitor is still in there, it’s living on borrowed time. Call (361) 326-1553 if you suspect a part is failing, free estimates on repairs.
Most electrical components, capacitors, contactors, sensors, and boards, are replaceable, not repairable. They’re sealed units built to a price point, and the failure mode is internal. A reversing valve can sometimes be freed if it’s stuck mechanically, though that fix rarely holds on a system that’s seen more than a couple of Austin summers. Our honest answer: if a part is repairable and that repair will hold, we’ll say so. If it’s a patch that’ll fail again next season, we’d rather put the money toward the right fix. Call us for a straight answer at (361) 326-1553.
Most single-part repairs, capacitors, contactors, defrost sensors, are done within 60 – 90 minutes of arriving at your door. A defrost control board replacement takes a bit longer because we verify the sensor readings and test defrost cycling before we leave. A reversing valve is a half-day job by the time the refrigerant is recovered, the valve is replaced, and the system is pressure-tested and recharged. We’ll tell you up front how long your specific repair will take. For same-day service in Austin, call (361) 326-1553.
Yes. Our Austin trucks carry the common Rheem failure parts: dual-run capacitors in the standard ratings, 24V and contactor replacements, defrost sensors, fan motor capacitors, and universal control boards where OEM cross-referencing allows. For less-common parts like a specific Rheem defrost board or reversing valve for an odd-tonnage unit, we can often source them same-day from local supply houses in Austin, or within one to two days if we need to order OEM from the regional distributor. We’ll tell you which situation you’re in before we quote the job. Call (361) 326-1553 and we’ll check availability while you’re on the phone.
We name the problem, name the price, and then we fix it – no surprises after the fact. If your Rheem heat pump is acting up in Austin, call us at (361) 326-1553 for a free estimate. A live person answers, 24/7.
Written by Devin Marlowe, Owner, Brandt HVAC Co Austin at Brandt HVAC Co Austin, serving Austin and nearby areas.